Cooling Tower Services
Our Cooling Tower Division is structured around delivering specialized cooling tower solutions with unmatched precision - ensuring you benefit from a team of highly skilled professionals with focused expertise. This specialized commitment means we understand the complexities of cooling tower systems inside and out—delivering solutions that are not only technically sound but also aligned with your operational goals. We don’t just maintain - we optimize. Our team ensures every project meets the highest standards of compliance, safety, and technological innovation. We are laser focused on maximizing your return on investment (ROI).
By combining deep industry knowledge with a targeted strategy, we deliver long-term performance, reliability, and peace of mind.
Save 10% more on Energy - How?
By having an optimal maintenance plan, you could be saving 10 percent more on energy usage! We can help customize your maintenance plan to better suit your cooling tower needs so that your cooling tower is running at full efficiency.
Maintenance plans include scheduled visits and regular check-ups that consist of the following services:
• Visual Inspection
• Mechanical Inspection
• Cleaning and Disinfection
• Safety Checks
• Documentation and Record Keeping
Be proactive—discuss your maintenance plan or schedule a cooling tower inspection with us today to ensure your equipment is fully prepared for the weather no matter the season.


Cooling Tower Maintenance Inspection
Regular inspections and maintenance are essential for keeping cooling towers operating efficiently, safely, and reliably. A proactive maintenance program helps reduce energy consumption, extend equipment lifespan, minimize costly repairs, and ensure compliance with health and safety standards.
A regular inspection schedule ensures ongoing reliability and early detection of potential problems.
• Monthly or Quarterly: Perform visual and mechanical checks to catch minor issues early and verify system performance.
• Annually: Conduct a comprehensive inspection, including structural assessment and a full cleaning of critical components.
Initial and Seasonal Start-Up
- Remove any debris, such as leaves and dirt from the air inlets.
- Flush the basin and strainer screens to remove any sediment or dirt.
- Remove the strainer screen, clean it, and reinstall it.
- Test the mechanical float valve to see if it operates freely.
- Inspect water distribution system nozzles and clean them.
- Check to ensure drift eliminators are securely in place and in the proper orientation.
- Adjust fan belt tension as required.
- Lubricate and check fan shaft bearings prior to seasonal start-up.
- Turn the fan(s) by hand to insure it turns freely without obstructions.
- Inspect the fan blades.
- Fill the basin manually up to the overflow connection.
After the Unit Has Been Energized, We Will Check the Following:
- Adjust the mechanical float valve as required.
- Unit basin should be filled to the proper operating level.
- Verify fan is rotating in the proper direction.
- Measure the voltage and current on all three power leads.
Seasonal Start-Up Checklist
When the system is to be shut down for the season, the following services should is performed.
- The cooling unit water basin will be drained.
- The water basin will be flushed and cleaned with the suction strainer screens in place.
- The suction strainer screens will be cleaned and re-installed.
- The water basin drain should be left open.
- The fan shaft bearings and motor base adjusting screws should be lubricated.
- The water makeup valve will be closed. All water make-up piping will be drained.
- Power off the cooling tower.
Additional Cooling Tower Services
(click for more)
- Routine Inspections & Assessments
- Mechanical Repairs (Fans, motors, gearboxes, etc.)
- Corrosion & Structural Repair
- Drift Eliminator, Fill, and Louvers Replacement
- Leak Detection & Sealing
(click for more)
- Chemical Water Treatment Programs
- Water Quality Testing & Analysis
(click for more)
- High-pressure Cleaning
- Descaling & Chemical Cleaning
- Legionella Prevention & Water Treatment
- Sludge & Debris Removal
- Disinfection Services
(click for more)
- New System Installation
- Cooling Tower Rebuilds & Replacements
- Component Upgrades
- Custom Fabrication & Retrofitting
(click for more)
- Thermal Efficiency Testing
- Upgrades for Energy Efficiency
- Vibration Analysis & Balancing
- Flow and Temperature Monitoring
- Retrofit & Modernization Solutions
(click for more)
- Regulatory Compliance (ASHRARE, OSHA, etc.)
- Legionella Risk Assessments
- Maintenance Logs & Service Reports
- Safety Audits
Start Saving Today
By implementing a comprehensive inspection process and maintenance plan, we help ensure the long-term reliability and safety of your cooling towers, minimizing downtime and operational costs.











